欢迎来到上海铄金电气技术有限公司!购买高频、超高频、超音频感应加热焊机到上海铄金电气技术有限公司
高频超音频加热设备机床电源
服务热线:138 1793 2268 超高频加热机厂家
新闻资讯news Center
联系方式:
免费咨询电话:
138 1793 2268 超高频加热机厂家
liugangct@163.com
news Center
新闻中心
当前页: 首页 > 工业用高频感应加热机故障案例分析

工业用高频感应加热机故障案例分析

六、故障排除:故障排除troubleshooting

故障现象The fault phenomenon

故障原因The cause of the problem

排除方法

Elimination method

    

No electrical source display

1.空气开关控制开关未合上The air switch control switch is not closed

2.控制保险丝断

The control fuse is blown

3.空气开关或控制开关损坏Air switch or control switch damaged

4.其他原因

Other reasons

1.合上开关

Close the switch

2. 更换保险丝

Replace fuse

3. 更换

replace

4.与厂家联系维修Contact the manufacturer for repair

启动不起来(即按启动按钮后,电流显示为“0”,机器声响很快,约几秒又自动停止)Can not start up (that is, after pressing the start button, the current display is "0", the machine sounds very fast, and stops automatically in about a few seconds)

1.感应圈两圈间短路Short circuit between induction rings

2.感应圈连接头松动Loose connection of induction coil

3.感应圈接头处有生料带There is raw tape at the induction ring joint

4.设备故障Equipment failure

1.整修感应圈

Refit the induction ring

2.上紧感应圈螺帽Tighten the induction ring nut

3.清除生料带

Remove raw material strips

4.与厂家联系维修Contact the manufacturer for repair

可以启动,有电流显示但不加热或加热很慢Can be started, with current display but not heated or heated very slowly

感应圈两圈间短路Short circuit between induction rings

整修感应圈

Refit the induction ring

工作时报警Working alarm

参见面板指示说明See panel instructions

 

工作即报警,反复多次现象一样Work that alarm, repeatedly many times

设备故障Equipment failure

与厂家联系维修Contact the manufacturer for repair

发布于2022-03-15 09:24:17

页面版权所有:上海铄金电气技术有限公司 | Copyright - 2018 All Rights Reserved 沪ICP备2023017330号-1